TRS 818 C - Continuous Duty Dual Outlet Transformer
Professional 8kV/18mA Continuous Duty Dual Outlet Inductive Transformer
The TRS 818 C provides continuous duty performance with 8kV output at 18mA across two outlets. Engineered for demanding applications requiring constant high-voltage supply with dual-outlet flexibility and superior thermal characteristics.
Key Technical Specifications:
- Output Voltage: 8kV
- Current Rating: 18mA (continuous duty optimized)
- Operation Type: Continuous duty
- Outlets: 2 high-voltage outlets
- Supply Voltage: 230VAC, 50Hz
- Supply Cable: 3 x 0.75 mm² conductors
- Overall Length: 440mm (380mm useable length)
- Weight: Approximately 1.8kg
- Insulation Class: Class H windings
- Encapsulation: Epoxy resin protection
- Compliance: EC Approval certified
- Mounting: Flush self-tapping screw outlets (13mm deep)