Dungs
Dungs GAO-A2-4-5 压力开关(美国规格)GW50A2 2- 20" 217087
Low stock (3 units)£22.55Unit price /UnavailableDungs
Dungs GW500 A5 压力开关 - 100-500 mBar - 227639
Very low stock (1 unit)£23.78Unit price /UnavailableDungs
Dungs LGW10 A2 1 - 10 mbar Differential Air Pressure Switch
Backordered£25.80Unit price /UnavailableDungs
Dungs LGW50 A2 2.5 - 50 mbar Differential Air Pressure Switch
Backordered£25.80Unit price /UnavailableDungs
Dungs LGW150 A2 30 - 150 mbar Differential Air Pressure Switch
Backordered£25.80Unit price /UnavailableSiemens
Siemens QPD15.003 Differential Pressure Switch
Backordered£28.60£37.61Unit price /UnavailableSiemens
Siemens QPD15.005 Differential Pressure Switch
Backordered£28.60£37.61Unit price /UnavailableSiemens
Siemens QPD15.010 Differential Pressure Switch
Backordered£28.60£37.61Unit price /UnavailableSiemens
Siemens QPD15.050 Differential Pressure Switch
Backordered£28.60£37.61Unit price /Unavailable
Huge Range
Pressure Switches for Air and Gas
Pressure switches are a vital part of many safety circuits, especially on burners, combustion systems and heaters. Switches are generally split into three categories; firstly, those that prove process air flow in a system, secondly, those that prove combustion air flow and finally, those that prove that the gas pressure to or from the system is within the correct range.
Process air switches may be dotted around the plant and can be mounted locally to the process fans or piped into the process ductwork.
Combustion air pressure switches are generally mounted on the burner unit or close to the combustion air fan, they can sense an air pressure or be mounted with two sensing points in order to measure pressure differential and hence air flow.
Gas pressure switches are generally mounted directly onto the burner gas valve assembly and measure pressure alone. The low gas pressure switch is usually sited before the gas valves and the high gas pressure switch after. It is quite common for gas pressure switches to be mounted directly onto Dungs multibloc valves.